UNITARY CONTROL
HEAT PUMP UNITS (HPU)
| 2 STAGE HEAT/2 STAGE COOL, CONSTANT VOLUME |
| 3 STAGE HEAT/3 STAGE COOL, ECON DAMPER CTL, CONSTANT VOLUME |
| 2 STAGE HEAT/3 STAGE COOL, ECON DAMPER CTL, 2 STAGE EMERGENCY ELECTIC HEAT |
| CUSTOM APPLICATIONS |
| MODBUS, LON, BACnet COMMUNICATION OPTIONS |
FAN COIL UNITS (FCU)
| MULTI-STAGE COOL , FAN CONSTANT/VARIABLE VOLUME |
| MULTI-STAGE COOL- /HOT WATER HEAT , FAN CONSTANT/VARIABLE VOLUME |
| MULTI-STAGE COOL / ELECTRIC HEAT , FAN CONSTANT/VARIABLE VOLUME |
| CHILLED WATER COOL / ELECTRIC HEAT , FAN CONSTANT/VARABLE VOLUME |
| MULTI-STAGE COOL- /HOT WATER HEAT , FAN CONSTANT/VARIABLE VOLUME |
| CHILLED WATER COOL / HOT WATER HEAT , FAN CONSTANT/VARABLE VOLUME |
| CUSTOM APPLICATIONS |
| MODBUS, LON, BACnet COMMUNICATION OPTIONS |
PACKAGE ROOF TOP
PACKAGED DX ROOF TOP UNITS (RTU)
| MULTI-STAGE COOL / HEAT, CONSTANT VOLUME |
| MULTI-STAGE COOL / HEAT, ECON DAMPER CTL, CONSTANT VOLUME |
| MULTI-STAGE COOL / HEAT, ECON DAMPER CTL, DUCT STATIC BYPASS DAMPER CTL |
| MULTI-STAGE COOL / HEAT, ECON DAMPER CTL, DUCT STATIC BYPASS DAMPER CTL, EF – BLD STATIC CTL |
| CUSTOM APPLICATIONS |
| MODBUS, LON, BACnet COMMUNICATION OPTIONS |
BOX CAR DX ROOF TOP AIR HANDLERS
| MULTI-STAGE COOL / HEAT, ECONO DAMPER CTL, CONSTANT VOLUME, |
| MULTI-STAGE COOL / HEAT, ECONO DAMPER CTL, DUCT STATIC CTL |
| MULTI-STAGE COOL / HEAT, ECONO DAMPER CTL, DUCT STATIC CTL, EXH FAN CTL for BLDG. STATIC |
| MULTI-STAGE COOL / HEAT, ECONO DAMPER CTL, DUCT STATIC CTL, EXH FAN CTL, EXH DAMPER CTL for BLDG. STATIC |
| OPTIONAL ADD HUMIDIFICATION OR DEHUMIDIFICATION CTL |
| MULTI-UNIT COMMON SUPPLY PLENUM |
| TRANE Intellipak Interface |
| Honeywell W7100 Retrofit Control |
| CUSTOM APPLICATIONS |
| MODBUS, LON, BACnet, OTHERS COMMUNICATION OPTIONS |
ZONE COMFORT CONTROL
VARIABLE VOLUME & TEMPERATURE (VVT)
| VVT PRESSURE DEPENDANT (SELECT TYPE OF PACKAGED OR BOXCAR UNIT CONTROL) |
| VVT PRESSURE INDEPENDENT (SELECT TYPE OF PACKAGED OR BOXCAR UNIT CONTROL) |
VARIABLE REFRIGERANT FLOW SYSTEMS INTEGRATION(VRF)
| MITSUBISHI VRF LON, MODBUS, BACnet |
| LG VRF LON, MODBUS, BACnet |
| DAIKIN VRF LON, MODBUS, BACnet |
VARIABLE AIR VOLUME (VAV) - PRESSURE INDEPENDANT
(PRESSURE DEPENDANT VAV KIT COMES WITH INLET CFM PROBE & SENSOR(S) TO CONVERT TO PRESSURE INDEPENDENT)
| SINGLE DUCT, CFM, DDC DAMPER CTL, COOL ONLY |
| SINGLE DUCT, CFM, DDC DAMPER CTL, HOT WATER HEAT |
| SINGLE DUCT, CFM, DDC DAMPER CTL, MULTI-STAGE ELECTRIC DUCT HEAT |
| DUAL DUCT, CFM, DDC DAMPER CTL |
| DDC HYBRID RETROFIT KITS, SINGLE DUCT, CFM, DDC DAMPER ACTUATOR, PNEUMATIC HOT WATER HEAT |
| DDC HYBRID RETROFIT KITS, SINGLE DUCT, CFM, PNEUMATIC INTERNAL DAMPER ACTUATOR, PNEUMATIC HOT WATER HEAT |
| DDC HYBRID RETROFIT KITS, DUAL DUCT, CFM, PNEUMATIC INTERNAL DAMPER ACTUATORS |
| CUSTOM APPLICATINS |
| MODBUS, LON, BACnet COMMUNICATION OPTIONS |
BUILT-UP CONTROLS
AIR HANDLER UNIT (AHU)
| 100% OA, CONSTANT/VARIABLE VOLUME, CHILLED WATER COOL |
| 100% OA, OA DAMPER CTL, CONSTANT/VARIABLE VOLUME, CHILLED WATER COOL, HOT WATER HEAT |
| 100% OA, OA DAMPER CTL, HOT WATER PRE-HTG, CONSTANT/VARIABLE VOLUME, CHILLED WATER COOL, HOT WATER HEAT |
| ECONOMIZER CTL, CHILLED WATER COOL, VARIABLE VOLUME , DUCT STATIC CTL, EXH FAN / DAMPER BLDG STATIC CTL |
| HEAT RECOVERY SYSTEMS |
ROOF TOP HEATER FURNACE (HF)
| CONSTAT VOLUME, MULTI-STAGE GAS VALVE, BYPASS DAMPER PRESSURE CTL |
| CONSTAT VOLUME, MODULATING GAS VALVE, BYPASS DAMPER PRESSURE CTL |
| MULTI-STAGE HEATER FURNACE CONROL |
| RADIANT HEAT TUBE SYSTEMS |
| CUSTOM APPLICATIONS |
| MODBUS, LON, BACnet, COMMUNICATION OPTIONS |
CENTRAL PLANT SYSTEMS CONTROL
BOILER SYSTEMS
| SINGLE BOILER, MULTI-STAGE, PRIMARY PUMP |
| SINGLE BOILER, MULTI-STAGE,CIRC PUMP, PRIMARY PUMP |
| SINGLE BOILER, MULTI-STAGE CONTROL, CIRC PUMP, PRIMARY PUMP, MIXING VALVE CTL |
| SINGLE BOILER, MODULATING FIRE CONTROL, CIRC PUMP, PRIMARY PUMP, MIXING VALVE CTL |
| SINGLE BOILER, MODULATING GAS VALVE(S) STAGE CONTROL, CIRC PUMP, PRIMARY PUMP, MIXING VALVE CTL |
| MULTI-BOILER SEQUENCES , ROTATION AND FAILURE RECOVERY APPLICATIONS |
| MULTI-PRIMARY PUMP ROTATION & FAILURE RECOVERY APPLICATIONS |
| PRIMARY & SECONDARY PUMPING APPLICATIONS |
| VARIABLE PUMPING CONTROL BASED ON PRESSURE AND/OR FLOW |
| INSTANT ON BOILER CONTROL |
| PROCESS BOILER APPLICATIONS |
| CUSTOM APPLICATIONS |
| MODBUS, LON, BACnet COMMUNICATION OPTIONS |
CHILLER SYSTEMS
| RACK CHILLER STAGE CONTROL |
| MUTIL-CHILLER RACK SEQUENCING & FAILURE RECOVERY APPLICATIONS |
| SCREW CHILLER STAGE CONTROL |
| MULTI-SCREW CHILLER STAGE CONTROL AND FAILURE RECOVERY APPLICATIONS |
| CENTRIFUGAL CHILLER STAGE CONTROL |
| MUTIL-CENTRIFUGAL CHILLER SEQUENCING & FAILURE RECOVERY APPLICATIONS |
| DUAL CENTRIFUGAL COMPRESSOR CHILLER STAGE CONTROL |
| DUAL CENTRIFUGAL COMPRESSOR CHILLER STAGE CONTROL AND FAILURE RECOVERY APPLICATIONS |
| TURBOR CORE COMPRESSOR CONTROL |
| MULTI-TURBOR CORE COMPRESSOR SEQUENCING AND FAILURE RECOVER APPLICAITONS |
| CARRIER RESISTIVE SETPOINT & DEMAND RESET |
| YORK SETPOINT & DEMAND RESET (PULSE WIDTH MODULATION) |
| TRANE SETPOINT & DEMAND RESET |
| MODBUS, LON, BACnet, OTHERS COMMUNICATION OPTIONS |
| CUSTOM APPLICATIONS |
CONDENSER / CHILLED WATER PUMPING SYSTEMS
| PRIMARY & SECONDARY PUMPING APPLICATIONS, ISOLATION VALVES CTL, STAGE AND FAILURE SEQUENCE APPLICATIONS |
| PRIMARY & VARIABLE SECONDARY PUMPING APPLICATIONS, ISOLATION VALVES CTL, STAGE AND FAILURE SEQUENCE APPLICATIONS |
| VARIABLE PRIMARY & SECONDARY PUMPING APPLICATIONS, ISOLATION VALVES CTL, STAGE AND FAILURE SEQUENCE APPLICATIONS |
| VARIABLE PUMPING BASED ON FLOW, PRESSURE, TEMPERATURE APPLICATIONS |
| VARIABLE PUMPING VFD COMMUNICATIONS, MODBUS, LON, BACnet |
COOLING TOWER CONTROL
| MULTI-COOLING TOWER TEMPERATUE OR PRESSURE CONTROL APPLICATIONS |
| COOLING SPRAY PUMP, FAN, DAMPER, BYPASS VALVE CONTROL |
| COOLING SPRAY PUMP, MULTI-SPEED FAN, DAMPER, BYPASS VALVE CONTROL |
| COOLING SPRAY PUMP, VFD FAN, BYPASS VALVE CONTROL |
| MULTI-COOLING TOWER STAGE AND FAILURE RECOVERY APPLICATIONS |
| CUSTOM APPLICATIONS |
VARIBLE FREQUENCY DRIVE INTEGRATION
| TRADITIONAL I/O INTERFACE AND CONTROL |
| MODBUS , LON, BACnet COMMUNICAITON OPTIONS |
BUILDING MONITORING
LIGHTING SYSTEM
| LUTON |
| WATTSTOPPER |
| GE |
| ANY OTHERS WITH LON, MODBUS, BACnet COMMUNICATION OPTIONS |
POWER & SUBMETERING
| CHARGING STATIONS |
| EMON-DEMO |
| DENT |
| Egauge |
| SQ-D |
| VERIS |
| KELE |
| ANY OTHERS WITH LON, MODBUS, BACnet COMMUNICATION OPTIONS |
SOLAR SYSTEMS
| ENPHASE MICRO INVETERS (API) |
| SUNNY BOY (MODBUS) |
| 4-20, 0-10VDC GENERATION OUT SIGNALS |
| ANY OTHERS WITH LON, MODBUS, BACnet COMMUNICATION OPTIONS |
TECH
HIGH TECH - CLEAN ROOM - LAB APPLICATIONS
| PRESSURIZATION APPLICATIONS: CLEAN ROOMS, PROCCESS, SURGICAL |
| HUMIDIFICATION APPLICATIONS: CLEAN ROOMS, PROCCESS, SURGICAL |
| DEHUMIDIFICATION APPLICATIONS: CLEAN ROOMS, PROCCESS, SURGICAL |
AUXLIARY
AUXLIARY SYSTEMS
| WATER RECLAIMATION / PUMPING SYSTEMS |
| GAS MONITORING PANELS / GARAGE CO CONTROLS |
| FIRE PANEL SECONDARY MONITORING |
| EMERGENCY GENERATORS & ATS SYSTEMS |
| SUMP PUMPING SYSTEMS |
COMM
COMMUNICATION INTEGRATIONS OPTIONS
| MODBUS (ALL) |
| LON |
| BACnet |
| JCI N2 |
| OPC SERVERS (KEPWARE, ETC.) |
| LEGACY BMS |